> Relays - General Purpose
-  Close This Window When Finished  -

MODEL Dimensions mm (inch) Features Contact Ratings Coil Ratings
Contact form Contact type Contact materials Max. operating current under resistive load Max. operating voltage Numbers of  poles Max. switching capacity under resistive load Minimum permissible load Rated load(under resistive load) Rated voltage Power consumption Dielectric Strenght (50/60 Hz for 1 minute) Electrical Service Life (operations) Terminal Choices Approved Standards
G4B

28.96 (1.14)H x 50.8 (2)L x 32.51 (1.28)W Breaks 15 A, carries 20 A and withstands 55 A inrush. 25 A high capacity and Class B insulation types available. SPST-NO, SPDT Single button AgCdO or AgInSn 15 A,  25 A (high capacity) 250 VAC, 125 VDC 1 3,300 VA/360 W 5,500 VA/600 W 100 mA, 5 VDC 15 A at 220 VAC, 24 VDC 25 A at 220 VAC, 24 VDC 6, 12, 24, 50, 100, 120 VAC 6, 12, 24, 48, 100, 110 VDC (At 60 Hz for AC) 1.3 VA, 1.2 W 2,000 VAC 100,000 minimum Quick-connect, PCB terminal, combination PCB + QC UL, CSA
G7J

64 (2.52)H x 53.5 (2.11)Lx 34.5 (1.36)W High capacity powerrelay has   double-break contact arrangement, and includes push-to-test button as a standard feature. 4PST-NO, 3PST-NO/SPST-NC, DPST-NO/DPST-NC Single button AgCdO 25 A (NO contacts) 8 A (NC contacts) 250 VAC, 125 VDC 4 5,500 VA (NO contacts) 1,760 VA (NC contacts) 100 mA, 24 VDC at 120 ops./min. 25 A at 220 VAC (NO contacts) 8 A at 220 VAC (NC contacts) 100/120, 200/240 VAC 12, 24 VDC 1.8 to 2.6 VA, 2.0 W 4,000 VAC 100,000 minimum Screw terminal, PCB terminal UL, CSA
G7L

49.02 (1.93)H x 68.58 (2.70)L x 34.54 (1.36)W High-capacity power relay has double-break contact arrangement. Class B insulation is standard. SPST-NO-DM DPST-NO-DM Single button AgCdO 30 A (SPST-NO) 25 A (DPST-NO) 250 VAC 1,  2 6,600 VA 5,500 VA, 100 mA, 5 VDC 30 A at 20 A at 220 VAC 220 VAC 6, 12, 24, 50, 100/110, 110/120, 200/220, 220/240 VAC 6, 12, 24, 48, 100/110 VDC 1.7 to 2.5 VA, 1.9 W 4,000 VAC 100,000 minimum Quick-connect, plug-in screw, PCB terminal UL, CSA, TUV, IEC, CE
LY

35.56 (1.40)H x 27.94 (1.10)L x 21.59 (.85)W Compact, general-purpose relay suitable for a wide range of applications up to 15 A. LED indicator, push-to-test button versions. SPDT, DPDT, 3PDT, 4PDT Single button, bifurcated button AgCdO 15 A (SPDT) 10 A (DPDT, 3PDT, 4PDT) 5 A (bifurcated contacts, DPDT and 4PDT) 250 VAC, 125 VDC

 

1, 2, 3, 4 1,700 VA 360 W  1,100 VA 240 W STD.: 100 mA, 5 VDC BIF.: 10 mA, 5 VDC 15 A at 10 A at 110 VAC, 110 VAC, 24 VDC 24 VDC 6, 12, 24, 50, 110, 120, 220, 240 VAC 6, 12, 24, 48, 110 VDC 1.1 VA 1.1 VA, 0.9 W 0.9 W (DPDT) 1.6 VA, 1.4 W (3PDT) 1.95 VA, 1.5 W (4PDT 2,000 VAC 200,000 minimum 500,000 min. (2P) PCB terminal, plug-in UL, CSA, SEV, VDE, CE
MK

52.58 (2.07)H x 34.54 (1.36)L x 34.54 (1.36)W Exceptionally reliable power relay plugs into convenient octal pin sockets. Mechanical indicator and test button are standard features. DPDT, 3PDT Single button Ag 10 A 250 VAC, 250 VDC

2,   3

2,500 VA 280 W 2,500 VA/1,250 VA 280 W 10 mA, 1 VDC 10 A at 5 A at 28 VDC 250 VAC (NC), 10 A at 120 VAC, 10 A at 28 VDC 6, 12, 24, 50, 110/120, 220/240 VAC 6, 12, 24, 48, 100/110 VDC 2.3 VA, 1.5 W 2,000 VAC 100,000 minimum Octal pin UL, CSA, SEV, DEMKO, TUV
MODEL Dimensions mm (inch) Features Contact Ratings Coil Ratings
Contact form Contact type Contact materials Max. operating current under resistive load Max. operating voltage Numbers of  poles Max. switching capacity under resistive load Minimum permissible load Rated load(under resistive load) Rated voltage Power consumption Dielectric Strenght (50/60 Hz for 1 minute) Electrical Service Life (operations) Terminal Choices Approved Standards
MY

36.07 (1.42)H x 27.94 (1.10)L x 21.59 (.85)W Versatile relay, ideal for power and sequence control applica-tions, meets many application needs. Latching and hermeti-cally sealed versions available. DPDT, 3PDT, 4PDT Single button, bifurcated button Ag or AgCdO 5 A (DPDT, 3PDT unsealed) 3 A (4PDT unsealed) 3 A (4PDT hermetically sealed) 1 A (4PDT sealed) 250 VAC, 125 VDC

2, 3, 4

1,100 VA 660 VA 120 W 72 W 2 & 3 pole types: 1 mA, 5 VDC; 4 pole types: 1 mA, 1 VDC; Bifurcated contact types: 100 mA, 1 VDC 5 A at 3 A 220 VAC, 220 VAC, 24 VDC 24 VDC 10 A at 10 A at 250 VAC, 250 VAC (NO), 6, 12, 24, 50, 100/120, 200/240 VAC 6, 12, 24, 48, 100 VDC Approx. 1.1 VA, 0.9 W 2,000 VAC 1,500 VAC 500,000 minimum 200,000 min. (4P) PCB terminal, plug-in UL, CSA, SEV, CE

 

 

NOTE:
1. Relay height includes standoffs.
2. All specifications subject to change without notice.
3.*All specifications measured at 23°C, 65% RH unless indicated otherwise.
4. Moving Loop Relay/ Super Loop Relay