| MODEL | Dimensions mm (inch) | Features | Contact Ratings | Coil Ratings | |||||||||||||
| Contact form | Contact type | Contact materials | Max. operating current under resistive load | Max. operating voltage | Numbers of poles | Max. switching capacity under resistive load | Minimum permissible load | Rated load(under resistive load) | Rated voltage | Power consumption | Dielectric Strenght (50/60 Hz for 1 minute) | Electrical Service Life (operations) | Terminal Choices | Approved Standards | |||
G5A![]() |
8.38 (.33)H x 16 (.63)L x 9.91 (.39)W |
Subminiature relay. Ideal for office automation and test and measurement. Semi-sealed or plastic sealed. |
DPDT | 1A | 125 VAC, 125 VDC | 2 | 37.5 VA, 33 W
|
10 mA, 10 mVDC | 0.5 A at 24 VAC 1 A at 24 VDC | 3, 5, 6, 9, 12, 24, 48 VDC | 200 mW (standard and latching)
|
1,000 VAC | 100,000 minimum | PCB terminal | UL, CSA, FCC Part 68 available | ||
G5V-1![]() |
9.91 (.39)H x 12.19 (.48)L x 7.37 (.29)W |
Subminiature relay for interface applications. Fully-sealed construc-tion. Low power consumption. |
SPDT | 1A | 125 VAC, 60 VDC | 1 | 62.5 VA, 30 W |
1 mA, 5 VDC | 0.5 A at 125 VAC 1 A at 24 VDC | 5, 6, 9, 12, 24 VDC | 150 mW | 1,000 VAC | 100,000 minimum | PCB terminal | UL, CSA | ||
G5V-2![]() |
11.43 (.45)H x 20.32 (.80)L x 9.91 (.39)W |
Miniature relay for handling low signals in computer peripherals, telecommunications and security equipment. Fully-sealed construction. |
DPDT | 2A | 125 VAC, 125 VDC | 2 | 62.5 VA, 60 W |
10 mA, 10 mVDC | 0.5 A at 125 VAC 2 A at 30 VDC | 3, 5, 6, 9, 12, 24, 48 VDC | 500 mW (standard) 360 mW (high sensitivity) 150 mW (ultra-sensitive) | 1,000 VAC | 300,000 minimum | PCB terminal | UL, CSA | ||
| MODEL | Dimensions mm (inch) | Features | Contact Ratings | Coil Ratings | |||||||||||||
| Contact form | Contact type | Contact materials | Max. operating current under resistive load | Max. operating voltage | Numbers of poles | Max. switching capacity under resistive load | Minimum permissible load | Rated load(under resistive load) | Rated voltage | Power consumption | Dielectric Strenght (50/60 Hz for 1 minute) | Electrical Service Life (operations) | Terminal Choices | Approved Standards | |||
G5Y-1![]() |
8.89 (.35)H x 20.32 (.80)L x 11.43 (.45)W |
Small RF relay with outstanding typical values for VSWR (1.8 max.), insertion loss (0.5 dB max.) and isolation (60 dB min.) at 900 MHz. Plastic sealed. |
SPDT | 0.1 A | 30 VAC, 30 VDC | 1 | 1 VA, 1 W |
10 mA, 10 mVDC | 0.01 A at 24 VAC 0.01 A at 24 VDC 1 W at 900 MHz at VSWR 1.2 | 5, 6, 9, 12, 24 VDC | 300 mW (standard) 200 mW (high sensitivity) | 1,000 VAC | 300,000 minimum | PCB terminal | --- | ||
G6A![]() |
8.13 (.32)H x 20.07 (.79)L x 9.91 (.39)W |
Fully-sealed relay with high reliability, ideal for communication equipment. Latching type available. |
DPDT 4PDT |
Bifurcated crossbar | Ag with Au clad Ag with Au clad |
2 A 2 A |
250 VAC, 220 VDC | 2 | 125 VA, 60 W | 10 mA, 10 mVDC | 0.5 A at 125 VAC, 2 A at 30 VDC 0.3 A at 125 VAC,1 A at 30 VDC |
3, 5, 6, 9, 12, 24, 48 VDC | 200 mW (DPDT std) 360 mW (4PDT std) | 1,000 VAC | 500,000 minimum | PCB terminal | UL, CSA, FCC Part 68 |
G6E![]() |
8.38 (.33)H x 16 (.63)L x 9.91 (.39)W |
Subminiature low signal switching relay has high sensitivity. Packed in a magazine for automatic insertion and soldering. Latching type available. |
SPDT | Bifurcated crossbar | Ag with Au clad | 3 A | 250 VAC, 220 VDC | 1 | 50 VA, 60 W | 10 mA, 10 mVDC | 0.4 A at 125 VAC 2 A at 30 VDC | 3, 5, 6, 9, 12, 24, 48 VDC | 200 mW (standard) 400 mW (low sensitivity) standard and latching 360 mW (high sensitivity) | 1,500 VAC | 500,000 minimum (DC) 100,000 minimum (AC) | PCB terminal | UL, CSA, FCC Part 68, CC I TT, Bellcore |
G6K![]() |
5.2 (.20) H x 10 (.39 ) L x 6.5 (.26) W | -Fourth generation design -Designed for worldwide communications, computer peripheral and office automation relay requirements| -Meets 2.5kV Bellcore surge requirements |
DPDT | Bifurcated crossbar | Ag with Au clad | 1 A | 125 VAC | 2 | 37.5 VA, 30 W | 10uA, 10 mVDC | 0.3A at 125VAC 1A at 30VDC |
3, 4.5, 5, 6, 9, 12, 24 VDC | 140 mW (standard)* | 1,000 VAC | 100,000 | PCB thru-hole, Gullwing, Inside "L" | UL, CSA |
| MODEL | Dimensions mm (inch) | Features | Contact Ratings | Coil Ratings | |||||||||||||
| Contact form | Contact type | Contact materials | Max. operating current under resistive load | Max. operating voltage | Numbers of poles | Max. switching capacity under resistive load | Minimum permissible load | Rated load(under resistive load) | Rated voltage | Power consumption | Dielectric Strenght (50/60 Hz for 1 minute) | Electrical Service Life (operations) | Terminal Choices | Approved Standards | |||
| G6H G6H-2F ![]() |
5.08 (.20)H x 13.97 (.55)L x 8.89 (.35)W |
Compact, extremely low profile relay ideal for high-density mounting. Bifurcated contacts capable of switching 1A with very little power consumption. Fully-sealed construction. Available in surface mount (G6H-2F). |
DPDT | Bifurcated crossbar | Ag with Au clad | 1 A | 125 VAC, 110 VDC | 2 | 62.5 VA, 33 W | 10 mA, 10 mVDC | 0.5 A at 125 VAC 1 A at 30 VDC | 3, 5, 6, 9, 12, 24, 48 VDC | 140 mW (standard)* | 1,000 VAC | 100,000 minimum "L" modified gullwing leads (G6H-2F) | PCB terminal (G6H) | UL, CSA |
G6S![]() |
9.4 (.370)H x 15 (.591)L x 7.5 (.295)W |
Third generation surface mount relay with innovative lead frame design. Engineered to meet the Bellcore 2.5 kV surge spec. Approx.17% smaller than competitive relays, allowing higher density, side- by-side mounting. |
DPDT | Single and bifurcated button | AgCdO | 2 A | 250 VAC, 220 VDC | 2
|
62.5 VA, 60 W
|
10 mA, 10 mVDC
|
0.5 A at 125 VAC 2 A at 30 VDC | 3, 4.5, 5, 6, 9, 12, 24 VDC
|
140 mW (standard) | 2,000 VAC (standard) | 100,000 minimum | Gullwing, inside "L" | UL, CSA, FCC Part 68, Bellcore |
NOTE:
1. Relay height includes standoffs.
2. All specifications subject to change without notice.
3.*All specifications measured at 23°C, 65% RH unless indicated otherwise.
4. Moving Loop Relay/ Super Loop Relay