> Sensors - Safety Related Devices
-
Close This Window When Finished -
| MODEL | Dimensions | Description | Switching Capacity | Contact Configuration | Mechanical Service Life (Operations) | Connection | Degree of Protection | Actuators | ||
| UL | NEMA | IEC 144 | ||||||||
| A22E
|
Mounts in 22 or 25mm cutout, 30, 40, 60mm dia mushroom pushbutton |
Push-Pull or Push-Lock, Turn-Reset operation, Safety lock mechanism prevents misuse, Finger protection is a standard feature, increased wiring efficiency with three row mounting for the switch unit, use either ring, spade terminals or ferrules, available in lighted, non- lighted, key-reset models | 10A at 24-440VAC 10A at 24-380VDC |
SPDT-NO SPST-NC DPST-NC |
300,000 minimum | screw terminals | UL508 | --- | IP65 (enclosure) |
--- |
A165E![]() |
Mounts in 16mm cutout, 30mm dia mushroom pushbutton |
Includes safety lock to prevent malfunction,
available in lighted (24VDC) & non- lighted models Red Switch knob has "Reset" indication, "Stop" indication also available |
5A at 125VAC 3A at 250VAC 3A at 30VDC |
SPST-NC DPST-NC |
300,000 minimum | solder terminals | --- | IP65 (enclosure) |
--- | |
| D4B-N
|
99.5 H x 40 W x 43 D mm (3.92 x 1.57 x 1.69 in) | Heavy-duty limit switch features direct drive
contacts that insure contacts open when welded due to overload currents. Snap-action switches retain high contact reliability during slow-moving operations. Slow-action switches have positive opening contacts for wider electrical separation between contacts. Three-conduit switch body available. Meets IEC, UL, CSA and VDE 0660 approvals. |
10 A continuous120, 240, 480, 600 VAC, NEMA A600 | SPDT, 1 normally open contact, 1 normally closed contact DPST, two normally closed contacts | 30 million minimum | 1/2 -14 NPT conduit entrance, terminal screws | 3, 4, 4X, 6P and 13 | 3, 4, 4X, 6P and 13 | IP67 | Side rotary nylon roller lever Adjustable side rotary rubber roller lever Adjustable side rotary nylon roller lever Adjustable side rotary rod lever Plain top plunger Top roller plunger Coil spring wobble lever Plastic rod wobble lever |
| D4BL
|
123.5 H x 112 W x 46.3 D mm (4.86 x 4.40 x 1.82 in) | Safety-door lock switch uses special
operation key to positively separate contacts, and features solenoid-locking mechanism to
keep safety door closed until signal is received from another device that protected area
is safe for workers to enter. The mechanism is nearly impossible to defeat. UL, CSA approval. |
10 A, 125 VAC inductive load, NEMA A300 | *DPDT, double break, 1 normally closed/1 normally open; DPDB, 1 normally closed *DPDT, double break, 2 normally closed, +DPDB, 1 normally closed | 1 million operations | 1/2 NPT conduit entrance, terminal screws | --- | --- | IP67 | Horizontal-mount key Vertical-mount key Adjustable key |
| D4D-N
|
60 H x 31 W x 30 D mm (2.36 x 1.22 x 1.18 in) | General purpose limit switch featuring a direct-opening contact mechanism which forcibly opens contacts even when welding has occurred. Low cost, plastic-body switch meets many European safety directives. Wide operating tempera-ture range. UL, CSA approval. | 10 A, 125 VAC, inductive load | DPDT, 2 normally closed DPDT, 1 normally open, 1 normally closed SPDT, 1 normally open, 1 normally closed | 15 million operations | PG 13.5, G 1/2, 1/2 -14 NPT conduit entrance, terminal screws | Type 4 (indoor use) | 3, 4, 6P, 13 | IP65 | Standard roller lever Adjustable roller lever Vertical roller lever Horizontal roller lever Plain top plunger Roller plunger Cat whisker wobble lever Plastic rod wobble lever |
| MODEL | Dimensions | Description | Switching Capacity | Contact Configuration | Mechanical Service Life (Operations) | Connection | Degree of Protection | Actuators | ||
| UL | NEMA | IEC 144 | ||||||||
| D4D-R
|
94.1 H x 40.0 W x 41.5 D mm (3.70 x 1.57 x
1.63 in)
|
Plastic-body, pull-reset limit switch featuring direct-opening contacts. Low-cost switch meets many European safety directives. Wide operating temperature range. UL, CSA approved. | 10 A max., 125 VAC | DPDT, double break, 1 NO/1 NC; DPDT, double break, 2 NC | 15 million minimum | 1/2-14 NPT conduit entrance, terminal screws | Type 4 (indoor use) | 3, 4, 6P, and 13 | IP65 | Pull reset with roller Adjustable roller Adjustable rubber roller Pull reset with plunger Roller One-way roller Horizontal and vertical roller |
| D4DS
|
85 H x 31 W x 36 D mm (3.35 x 1.22 x 1.42 in) | Safety-door limit switch that uses special operation key to positively separate contacts. Low-cost, plastic-body switch meets many European safety directives. Wide operating temperature range. UL, CSA approved. | 10 A max., 125 VAC | DPDT, double break, 1 NO/1 NC; DPDT, double break, 2 NC | 15 million minimum | 1/2-14 NPT conduit entrance, terminal screws | Type 4 (indoor use) | 3, 4, 6P, and 13 | IP65 | Horizontal mount key Vertical mount key Adjustable key |
|
|
Full length of units range from 228.5mm (9.00) for 16 beam @ 10mm spacing to 1,028.5mm (48.49) for 48 beam @20mm spacing | Self-contained design requires no control
box, multiple units can be connected for a larger protected zone, heights from 140mm
(5.51) to 940mm (37.0) Meets OSHA, Canadian and worldwide standards for safeguarding personnel |
Infrared LED 16, 32, 48 beams with 10mm spacing, 8, 16, 24, 32, 48 beams with 20mm spacing |
10mm Beam Spacing: 16-150mm 32-310mm 48-470mm 20mm Beam Spacing: |
10mm Beam Spacing: Non-transparent 15mm (0.39) diameter 20mm Beam
Spacing: Sensing Range:0.2m to 5.0m (7.87 to 16.40 ft) |
24VDC Two PNP transistor outputs, 300mA max. load |
Connector on 400mm (15.75) cables; use extension cables | |||
G7S![]() |
37 H x 62 W x 22.5 D mm (1.46 x 2.44 x 0.89 in) | Plug-In Safety Relay with positive, force guided contacts suitable for safety circuits in press machinery, machine tools, and other production machinery | Resistive: 3A at 240VAC & 24VDC Inductive: 3A at 240VAC, 1A at 24VDC |
4PST-NO + DPST-NC 3PST-NO + 3PST-NC |
10 million minimum | DIN rail mtg and screw terminals, solder terminals, PCB terminals | UL508 | --- | IEC 255 | --- |
| G9S
|
101 H x 111 D mm (3.98 x 4.37 in) 2 Pole : 22.5 W (0.88) |
Ideal for safety door & emergency stop
switch circuits, 2, 3, 5 Pole models incorporate LED indicators & replaceable fuses Off-delay model also available |
2 Pole, 24VDC model 66mA 3 Pole, 24VDC at 62.5mA to 240VAC at 12.5mA 5 Pole, 24VDC at 127mA to 240VAC at 22.9mA |
2 Pole: DPST-NO, 24VDC coil voltage 3 Pole: 3PST-NO 1 SPST-NC Aux |
10 million minimum | DIN rail mount Screw mount for 2 Pole model |
UL508 | --- | --- | --- |
| MODEL | Dimensions | Description | Switching Capacity | Contact Configuration | Mechanical Service Life (Operations) | Connection | Degree of Protection | Actuators | ||
| UL | NEMA | IEC 144 | ||||||||