Pressure Washer Pump Motors
Single Phase
 

 
iProcesSmart Home Page of Industrial Process Equipment 
Temperature
Level
Pressure
Flow
Environmental
Instruments
Filtration
Valves
Electrical
Logic
Motion
Controls
TechSmart
Manufacturers
Company Info
Terms of Service
Site Security
Your Privacy
Support
Customers
Suppliers
News

 

 

SEARCH  INVENTORY



 

 

 

 

 

 

 

View Information or Specification information in Adobe Acrobat PDF FormatWhenever you see me you will find a PDF file. Click here to download  the latest Adobe Acrobat Reader

 

PRESSURE WASHER PUMP MOTORS
SINGLE PHASE • LOW AMPERAGE DESIGN

RIGID BASE SINGLE PHASE • DRIP-PROOF
Click here for standard products!

C FACE WITH
BASE •
SINGLE PHASE DRIP-PROOF
Click here for standard products!

C FACE WITH BASE SINGLE PHASE TEFC

Click here for standard products!

General Specifications:
Motors specially suited for hot or cold pressure washer applications and other single phase installations requiring minimum starting and running amperages. Capacitor start, capacitor run construction for reduced amperage.

Mechanical Features:
Double shield ball bearings prelubricated with Shell Dolium R lubricant, having operating temperature range of -20°F to +350°F and special formulation to provide extra long life and moisture resistance. Dynamically balanced rotor and shaft assembly.

Electrical Features:
High efficiency reduced amperage energy saving designs. Stator impregnated with extra heavy varnish system. High temperature copper magnet wire for high overload capacity. Capacitor start/capacitor run design for reduced amperage. Grounding provision in conduit box. Manual reset overload protector protects against automatic resets. High overload capacities provided by service factor.


LEESON's Inverter Rated Insulation system (IRIS™)
provides superior protection against voltage spikes induced by variable frequency drives. This total insulation system protects better than spike-resistant magnet wire alone. Specially formed phase insulation, cushioned and sleeved connections (from the leads all the way into the turns), and deep-penetrating, non-hygroscopic, high temperature varnish are just a few features contributing to extra protection. All this plus second generation spike-resistant magnet wire. The IRIS™ total insulation system is standard at no extra cost in all LEESON stock NEMA three-phase motors, 1 HP and larger.

 


RIGID BASE • SINGLE PHASE • DRIP-PROOF
Click to enlarge!
Ordering Information - Pressure Washer Pump Motors • Rigid Base • Single Phase • Drip-Proof
HP
RPM
60
Hz
NEMA
Frame
Catalog
Number
Order Now!
Disc.
Sym.
App.
Wgt.
(lbs.)
Voltage
Over-
load
Prot.
F.L.
Amps
115 V.
"C"
Dim.
(Inches)
3/4
1725
S56
LEAC101544.00 §
Click here to order online!
A
26
115/208-230
Man.
3.8
10.88
1
1725
56
LEAC113630.00 §
Click here to order online!
A
40
115/208-230
Man.
5.3
10.88
1 1/2
3450
56
LEAC113631.00 §
Click here to order online!
A
36
115/208-230
Man.
6.7
11.38
1 1/2
1725
56H
LEAC113266.00 §¥
Click here to order online!
A
42
115/208-230
Man.
6.7
12.38
2
3450
56
LEAC113632.00 §
Click here to order online!
A
38
115/208-230
Man.
8.6
11.38

§ Capacitor start/capacitor run design for reduced amperage, others are capacitor start/induction run.
¥ Combination 56H base motors have mounting holes for NEMA 56 and NEMA 143-5T and a standard NEMA 56 shaft.

C FACE WITH BASE • SINGLE PHASE • DRIP-PROOF
Click to enlarge!
Ordering Information - Pressure Washer Pump Motors • C Face With Base • Single Phase • Drip-Proof
HP
RPM
60
Hz
NEMA
Frame
Catalog
Number
Order Now!
Disc.
Sym.
App.
Wgt.
(lbs.)
Voltage
Over-
load
Prot.
F.L.
Amps
115 V.
"C"
Dim.
(Inches)
1 1/2
1725
56HC
LEAC113700.00 §¥
Click here to order online!
A
42
115/208-230
Man.
7.2
11.88
2
1725
56HC
LEAC113281.00 §¥
Click here to order online!
A
47
115/208-230
Man.
8.6
12.88

§ Capacitor start/capacitor run design for reduced amperage, others are capacitor start/induction run.
¥ Combination 56H base motors have mounting holes for NEMA 56 and NEMA 143-5T and a standard NEMA 56 shaft.

C FACE WITH BASE • SINGLE PHASE • TEFC
Click to enlarge!
Ordering Information - Pressure Washer Pump Motors • C Face With Base • Single Phase • TEFC
HP
RPM
60
Hz
NEMA
Frame
Catalog
Number
Order Now!
Disc.
Sym.
App.
Wgt.
(lbs.)
Voltage
Over-
load
Prot.
F.L.
Amps
115 V.
"C"
Dim.
(Inches)
1 1/2
3450
56C
LEAC115024.00
Click here to order online!
A
35
115/208-230
Man.
6.7
12.31
2
3450
56HC
LEAC114995.00
Click here to order online!
A
42
115/208-230
Man.
9.2
13.31
3
3450
56HC
LEAC115048.00
Click here to order online!
A
53
208-230
Man.
14.0
13.81

§ Capacitor start/capacitor run design for reduced amperage, others are capacitor start/induction run.
¥ Combination 56H base motors have mounting holes for NEMA 56 and NEMA 143-5T and a standard NEMA 56 shaft.

 Click here to return to the main page! Home

 

 

Government Buyers - Click Here

 

 

Important Notice: By purchasing products from this Site, you acknowledge and agree that you have read and accept the Terms and Conditions of this online store. For more information email us at: info@iprocessmart.com

 


Copyright © 1999 iProcesSmart™.com
web@iprocessmart.com

Design & Maintenance by
WEBench Design
Last modified: May 06, 2000