Series P2000

Differential Pressure Gauges

INSTALLATION MANUAL

DATA SHEET

Series S2000 Mechanical Differential Pressure Gauges The Series P2000 is a low cost, diaphragm operated, differential pressure gauge in an ABS housing.  The P2000 can be used in applications for measuring positive, negative, or differential pressure with an accuracy of 2%. Standard applications include monitoring filter status, duct static pressure, room pressure, fan or blower pressure, paint booths, dust collectors, and cabinet purging along with many others.
Specifications
Pressure Limits: -20" Hg to 15 PSI (-0.677 bar to 1.034 bar)
Media compatibility: Air and compatible gasses
Accuracy: +/- 2% full scale (+/- 3% on -0 and +/- 4% on -00) throughout range at 70°F (21°C)
Temperature Ranges: 20° to 140°F (-7° to 60°C)
Housing Material: ABS case, bezel, and cover
Process Connection: 1/8" female NPT duplicate high and low pressure taps - one pair side and one pair back.
Weight: 10 oz (283 g)
Accessories: Two 1/8" NPT barbed fittings, two 1/8" NPT plugs, and three mounting tabs and screws
Dimensional Drawing
series S2000 - Dimesional Drawing
Model Numbers
Model Number Pressure Range Model Number Pressure Range
P2000-00 0 - 0.25" P2020 0 - 20"
P2000-0 0 - 0.5" P2025 0 - 25"
P2001 0 - 1" P2030 0 - 30"
P2002 0 - 2" P2050 0 - 50"
P2003 0 - 3" P2100 0 - 100"
P2004 0 - 4" P2300-0 0.25 - 0 - 0.25"
P2005 0 - 5" P2301 0.5 - 0 - 0.5"
P2006 0 - 6" P2302 1 - 0 - 1"
P2008 0 - 8" P2304 2 - 0 - 2"
P2010 0 - 10" P2310 5 - 0 - 5"
P2015 0 - 15" P2320 10 - 0 - 10"
*Other pressure ranges available upon request.
   
   

 

 
 
 