| Relative humidity measurement |
Measurement rannge |
0 ... 100 % RH
|
| Accuracy at +20 °C (68 °F) |
± 1.0 % RH (0 ... 90 % RH) |
| Accuracy at +20 °C (68 °F) |
± 1.7 % RH (90 ... 100 % RH) |
| Sensor (general use) |
HUMICAP® 180 and HUMICAP® 180R |
| Sensor (demanding chemical environment) |
HUMICAP® 180L2 |
| Temperature measurement |
Measurement range
HMT361
HMT363
HMT364/365/367/368
|
-40 ... +60 °C (-40 ... +140 °F)
-40 ... +120 °C (-40 ... +248 °F)
-40 ... +180 °C (-40 ... +356 °F)
|
| Typical accuracy of electronics at +20 °C (68 °F) |
± 0.2 °C (± 0.36 °F) |
| Sensor |
Pt 1000 RTD 1/3 Class B IEC 751 |
| Other optional variables available |
Dewpoint temperature, mixing ratio, absolute humidity, wet bulb temperature. |
| Operating environment |
Temperature
for electronics
with display
storage |
-40 ...+ 60 °C (-40 ... +140 °F)
-20 ...+ 60 °C (-4 ... +140 °F)
-40 ...+ 70 °C (-40 ... +158 °F)
|
| Inputs and outputs |
Operating voltage
with serial port (servicemode)
|
12 ... 28 V
15 ... 28 V
|
| Analog outputs |
two-wire 4 ... 20 mA, one standard, one optional |
| Digital outputs |
RS-232C serial output for service use |
| Mechanics |
Weight (housing)
|
950 g
|
| Material (housing) |
G-AlSi 10 Mg (DIN 1725) |
| Housing classification |
IP66 (NEMA 4X) |
| Options and accessories |
Additional analog output
|
4 ... 20 mA
|
| Duct mounting installation kit (for HMP363/367) |
210697 |
| Installation flange (for HMP365) |
210696 |
| Ball valve set (for HMP368) |
BALLVALVE-1 |
| Serial interface cable for PC |
25905ZZ |
| Protection cover |
214101 (for use in the presence of combustible dust) |
| Galvanic isolator |
212483 |
| Zener barrier (USA & Canada) |
210664 |